FRENES

Choosing the right targets.

Complexity Lab is an independent research laboratory that compares, on published patient data, the methods for choosing the targets of a personalized therapeutic vaccine — and publishes its failures as well as its successes.

Research, not medicine.

This work treats no one, replaces no doctor, and gives access to no treatment and no clinical trial. There is nothing for sale here. If you or someone close to you is affected by cancer, the only right place to turn is your care team.

In one minute

Complexity Lab:
what is it?

THE SUBJECT

A choice that decides everything

Personalized therapeutic cancer vaccines are a field of research: the aim is to teach the immune system to recognize the mutations specific to one tumor. Such a vaccine carries only a handful of targets, chosen from tens or thousands of candidates. Which ones to choose?

WHAT THE LABORATORY DOES

A test bench, not a treatment

It makes nothing and treats no one. It is a computational test bench that compares methods for choosing targets on patient data already published by other teams, writing down its predictions before each measurement and publishing its failures as well as its successes.

WHAT IT IS FOR

Taking no method on trust

Knowing what these methods are really worth, including its own: being the referee of the race, not a runner. Its most solid results are refutations, and they are published here, with their sources.

FOLLOW THE RESEARCH

The Living Forest

A page that follows the laboratory's register in real time. Each tree there is a published patient, with its study reference and the hash of its case, entered in the register. Enter →

Who? An independent research project, run by Damien Chapus, with no funding, no industrial partner and nothing to sell. The name comes from the science of complex systems, where the project started: a problem that tips over all at once, like water freezing. It is becoming a French non-profit association, registration in progress, based in Antibes (France).

In eleven slides

What we are after,
and what did not hold.

The method without prerequisites, and the figures as they stand on 28 November 2026. Every slide carries its source: what you see here is recomputed from the registry. Scroll sideways.

01 — The problem

Every tumour carries its own targets

A cancer's mutations belong to the person who carries it. A therapeutic vaccine must therefore aim at targets chosen patient by patient.

The software proposes thousands of them. Only a handful can be made. The whole difficulty lies in the ordering.

Measured median: 2,241 candidates per patient.

02 — The question

Getting the right targets to the top of the list

We are not trying to predict whether a target will work. We are trying to rank candidates, so that those that matter land in the top twenty.

That is a question which can be measured, got wrong, and refuted.

153 patients · 5 public cohorts · 342,848 candidates.

03 — The method

The verdict is written before the computation

Before each measurement we seal an envelope: the hypothesis, the threshold that would confirm it, the one that would refute it. It is timestamped, and only then do we compute.

Moving the goalposts afterwards is impossible.

65 envelopes filed, 61 judged, 4 pending.

04 — The registry

What it actually gives

287 sealed criteria
270 confronted

191 held. 79 were refuted — one criterion in three. All 79 are published, not deleted.

Sealed registry, state on 28/11/2026.

05 — Refuted

Clonality is of no use here

We believed it decisive for prioritisation. Once measured: recognised targets and the rest have the same clonality, and most candidates are already clonal. There is nothing to separate.

Its weight in the score has been set to zero.

Measured across the five cohorts; direction unstable from one to the next.

06 — Refuted

The simulation assumed what it was measuring

−74.3 %

The lab's most cited result rested on a rule hard-coded into the simulator. Without it, three quarters of its reach are gone.

The drop was announced in an envelope sealed before the computation was redone.

07 — Refuted

What is learnt here does not travel there

0 positive folds out of 9

A model trained on several cohorts and tested on a held-out cohort brings nothing. Two protocols, same verdict.

Leave-one-cohort-out validation, held-out cohort never seen.

08 — Refuted

The predictor errs ten times more than claimed

Against 5,115 affinities actually measured in the laboratory, the predictor's error reaches ten times the assumed value, against the three times claimed by its authors.

Published binding measurements, compared one by one.

09 — The honest result

No superiority is claimed

64.71 % · 64.71 %

On the criterion that matters — at least one recognised target in the top twenty — the lab's score does exactly what affinity alone does. Ten patients gained, ten lost.

Per patient: +0.09 targets, confidence interval [−0.02; +0.21], which contains zero.

153 patients, paired comparison.

10 — The contribution

What is new is the verification

10,849,629

links in the hash chain. Every hypothesis is sealed in it before computation, and the whole is anchored in the Bitcoin blockchain.

Anyone can verify the date without having to trust us.

OpenTimestamps anchoring; every published figure carries the command that recomputes it.

11 — What is missing

It needs data we do not have

Across the public cohorts, no patient carries recognition screening, clonality and the presentation pathway at once. Any measurement made alone would be circular.

Hence the proposal made to laboratories: a blind test on 15 to 20 patients, with the ranking sealed before the answers are known.

Intersection measured across the five cohorts: empty.

New · for ages 10 and up The Forest and its Guardians The laboratory told with trees, strange leaves, guardians and pebbles — results included, mistakes included. Enter the forest →

The question

A vaccine encodes
only a small number of targets.

So the question is not “is this target good?”, but rather: among all the possible targets in this patient, which ones to keep — and in what order?

A ranking can only be evaluated on a patient for whom we know all the targets tested in the laboratory: those that triggered an immune response as well as those that triggered nothing. It is this confrontation that this test bench automates.

The difference

What this laboratory brings,
and what is rarely found together.

Choosing the targets of a personalized therapeutic vaccine is something many teams do, academic and industrial, with tools that already exist. What is most often missing is a public and verifiable way of knowing what each method of choice is really worth.

The idea is not new, and that must be said: in 2020, the TESLA consortium compared methods blind, once, on targets then tested in the laboratory. This bench takes up that idea and makes it permanent, with six rules held together.

1 · THE BET BEFORE THE COMPUTATION

Every prediction is sealed first

Written, timestamped and chained by hashes before the computation runs; the anchoring in Bitcoin comes afterwards — the calendars group the hashes before writing them into a block, which takes from a few hours to a few days. The refutations are published one by one, next to the predictions that held, on the Priority page.

2 · FAILURES COUNT

Targets that triggered nothing are kept

Patient by patient. A ranking can only be judged on the complete list: a database that kept only the successes could measure no error.

3 · FIVE COHORTS, NOT ONE

A method must hold up away from home

It is judged on five cohorts of real patients, with no patient in common, and on its ability to carry over from one to another. Today, this transfer fails: no transfer test is positive, zero folds out of nine, on two protocols. It is written further down, in full.

4 · THE LABORATORY AGAINST ITSELF

Its own controls correct it, in public

Three quarters of the gain of its most cited result (74.3%) disappear when the simulation stops assuming what it measures. And the error of its binding-affinity predictor, written by hand, had never been measured: confronted with laboratory affinities, it can reach about three times what was assumed. This is an upper bound, which includes the experimental error; we went from no measurement to a bracket. Both were found by the laboratory itself, and are published up front, not in a footnote.

5 · A RESULT AGAINST THE CURRENT

Clonality decides nothing

The field uses it to prioritize targets. On the real cohorts, it does not separate recognized targets from the others, and its direction changes from one cohort to another. A negative result, measured and sealed: it is, to date, the laboratory's most solid finding.

6 · NOTHING TO SELL, EVERYTHING TO REDO

No in-house method to defend

Public data under open licences, offline computation, a register verifiable by a third party. The bench judges the laboratory's methods by the same rule as those of others, and it has already refuted them several times.

THE ULTIMATE GOAL

That no method for choosing targets be taken on trust.

This laboratory will not make a vaccine: it has neither the means nor the vocation. Its goal is a public test bench where any method for selecting targets, its own as well as those of others, is measured on real patients already published, with its bets sealed before the computation and its failures on display.

Being the referee of the race, not a runner. If one day it becomes a useful waypoint for the research teams working on these vaccines, it will have done its job.

The road

The map of the road,
and the square where this laboratory stands.

Personalized therapeutic cancer vaccines are a field of research. Here, in two readings, are the steps it requires, and the exact place of this laboratory. No percentage: we locate the square, we do not measure a distance that no one knows.

READING 1 · FOR ONE PATIENT, THE MANUFACTURING CHAIN

Eight steps, only one studied here

1 · Sample

A piece of tumor and some healthy tissue, to compare the two.

out of reach

2 · Sequence

Read the DNA of the tumor and of the healthy tissue, and the RNA of the tumor.

out of reach

3 · Find the mutations

What is specific to the tumor, and absent from the healthy tissue.

out of reach

4 · Draw up the list of candidates

The mutated fragments that the patient's HLA molecules could show to their lymphocytes. From a few tens to several thousand per patient.

studied upstream

5 · Choose and rank the targets

Keep the small handful that will go into the vaccine. This is the only step this laboratory studies, and it studies it after the fact, on already published patients whose laboratory results are known, never for a patient currently in care.

📍 here

6 · Manufacture

A messenger RNA or peptides that carry the chosen targets.

out of reach

7 · Check quality

Each batch, before any administration.

out of reach

8 · Administer and follow up

Within a clinical trial, by a care team.

out of reach
READING 2 · FOR A METHOD OF CHOICE TO BE USEFUL, THE ROAD OF PROOF

The laboratory is on the first square, and has not finished it

1 · Measure the methods on published data

Done: a bench that compares the methods on five real cohorts, with no patient in common, with predictions sealed before each measurement. Not done: a method that holds from one cohort to another, and a list judged prospectively, that is, chosen before the laboratory tests it. The 14 milestones in the Progress section detail this single square.

📍 here · in progress

2 · Test the chosen targets on real cells

Check in the laboratory that the selected targets awaken a patient's lymphocytes. This requires a wet lab and samples: this project has neither, and has itself tested no target.

not started

3 · Make a candidate and test it in animals

Tolerance, immune response, dose: the so-called preclinical studies.

not started

4 · Phase I

Safety, in a small number of volunteers.

not started

5 · Phase II

A first signal of efficacy, in more participants.

not started

6 · Phase III

The large-scale comparison with the standard treatment.

not started

7 · Approval and monitoring

By the medicines agencies, then surveillance after marketing.

not started

The honest assessment: no target tested by this laboratory, no patient, no vaccine, no list validated prospectively. The teams that reached clinical trials spent years on it, with hospitals, laboratories and funding that this project does not have. What it can bring to this road is a first square held with rigour, and public measurements that others can take up or contradict.

The proof

Three levels,
never confused.

Mixing a simulation and a real trial is lying to yourself with exact numbers.

LEVEL 1

Simulated patients

∞
perfect answer key

The mechanism is invented. Used to check the machinery — never to draw conclusions.

LEVEL 2 · REAL

Target-by-target assays

87,899
documented failures · 56%

Out of 156,403 assays run on real cells. A database that kept only the successes would measure no error.

LEVEL 3 · REAL

Ranking per patient

34
targets recognized / 702 tested

The only possible judge of a complete ranking: real patients for whom every verdict is known.

Provenance

Where the data
come from.

No data are produced here. Everything comes from work published under open licences, and every number displayed is counted on the file itself rather than copied from an article.

SourceWhat it establishesLicense
CEDAR / IEDB cedar.iedb.org
funded by the NCI (NIH)
export of 23/09/2026
Target-by-target ground truth: 156,403 assays, 87,899 documented failures. Each row traces back to its article. CC BY 4.0
Harmonized matrices Müller, Bassani-Sternberg et al.
Immunity 2023
DOI 10.1016/j.immuni.2023.09.002
Per-patient ranking ground truth, on three cohorts: NCI, re-annotated TESLA subset, HiTIDE. CC BY 4.0 · GPL
TESLA consortium Wells et al.
Cell 2020
DOI 10.1016/j.cell.2020.09.015
Original producers of the epitopes judged blind, then tested on patient samples. see the article
IMPROVE Borch, Carri, … Hadrup
Front. Immunol. 2024
DOI 10.3389/fimmu.2024.1360281
Fourth cohort, assembled in Denmark: 70 patients, 17,520 candidates screened one by one, 467 recognized, negatives kept patient by patient. Read by the bench. CC BY 4.0
IOTech2025 Ketelaars, van Buuren, … Haanen
Immuno-Oncology Technology 2025
DOI 10.1016/j.iotech.2025.101062
Fifth cohort, the first outside melanoma: 26 patients of whom 19 evaluable, 8,103 candidates tested, 34 recognized; melanoma, mesothelioma, urothelial cancer, triple-negative breast cancer. Read by the bench since 13/10/2026. No clonality measurement. CC BY-NC-ND 4.0
Osteosarcoma public donation by Sid Sijbrandij
Rare Cancer Research Foundation
A complete real genome. Underpins published results: 628 real peptides, 12,420 candidates. CC0
HLA Ligand Atlas hla-ligand-atlas.org
PRIDE PXD020186 · PXD024837
version 2020.12
The measured self filter: 223,246 peptides actually eluted from 29 benign tissues and identified by mass spectrometry — not predicted. CC0
Human proteome UniProt / Swiss-Prot The self filter. Without it, one cannot say a peptide is a neoantigen — only that it is mutated. CC BY 4.0
GSE78220 Hugo et al.
Cell 2016
DOI 10.1016/j.cell.2016.02.065
Measured gene expression on 28 melanoma biopsies, with the response to treatment. It carries this laboratory's first three measurements on a clinical outcome (seals no. 37 to no. 39). GEO, open access
GSE91061 Riaz N, Havel JJ, … Chan TA
Cell 2017
DOI 10.1016/j.cell.2017.09.028
65 patients, 109 samples on nivolumab — of which 51 before treatment and 58 during. Connected on 14 October to replicate seal no. 37 on two and a half times as many patients, and to ask a question that 26 patients did not allow: does the signature predict better before or during treatment? GEO, no stated restriction
What this laboratory does not have. The patients' raw sequencing data are re-identifying: they remain behind the accreditation of their original repository and are not used here. The data used are derived tables — target → patient → verdict. And the re-annotated TESLA subset carries 34 recognized targets where the original article reports 37: it is this subset that is used, and it is named as such.

Transparency

Everything running
under the hood.

The language models, the predictors, the libraries. Nothing is hidden: a result that cannot be reproduced is not a result.

LANGUAGE MODEL

Qwen 2.5 7B, local

disabled by default

Via Ollama, on the machine, without network. It is used only to put into sentences the logbook. No number, no result, no scientific decision goes through it. If it does not respond, the raw text is published as is.

DEVELOPMENT

Written with Claude Code

Anthropic

The code of this laboratory was written in tandem with an AI assistant. It is stated here because it is part of the method — and because every result remains verifiable independently of how the code came to be.

WHAT IS REALLY EXPOSED

Mass spectrometry

223,246 peptides, 29 healthy tissues

Peptides eluted from real cells and weighed one by one. A peptide already presented on healthy tissue is tolerated by the body: targeting it means betting on a reaction the body has learned not to have. The laboratory's only source that measures instead of predicting.

BIOLOGICAL PREDICTION

MHCflurry 2.x

Apache 2.0 · run locally

A specialized neural network, not a language model. Used to independently recompute the published affinities: it is from this comparison that the measured median gap comes. If it is absent, the fallback is announced as such.

ComponentRoleLicense
python-satMiniSat 2.2 · Glucose 4 Satisfiability solvers — the laboratory's original engine.MIT
scikit-learnHistGradientBoosting Learning on hand-judged reports.BSD-3
UMAP · HDBSCAN Projection and clustering of instances, to see families.BSD-3
NumPy · pandas · SciPy · Numba Computation, statistics, just-in-time compilation.BSD-3
Streamlit · Plotly The interface and its charts.Apache 2.0 · MIT
SQLite + SHA-256 The sealed register: verifiable hash chain, exportable certificate.public domain
Pipervoice fr_FR-siwis-medium Speech synthesis for the film, on the machine — no online AI voice.MIT
Sarek · VEP · pVACseq Reference pipeline that produced the epitopes of the real genome used.MIT · Apache 2.0
CuPyoptional GPU acceleration when the card is present. Otherwise, the computation runs without it.MIT
The laboratory runs offline. Once the data are in place, it contacts no service: a test in the suite fails at the slightest network access. No data goes to a third party, no remote model is called, and the site you are reading runs no script — except the game page, the Living Forest, whose script is served from this domain and contacts no one.

Progress

Where the work
stands.

Not a percentage of progress “towards a vaccine”: no one knows what fraction of that road has been covered, and an invented number would be read as a promise. What follows is verifiable — the milestones of the test bench, reached or not.

13
milestones reached out of 14 identified · 0 in progress

The engine and the sealed register

SHA-256 hash chain, certificate exportable and verifiable by a third party.

done

The end-to-end pipeline

From mutation to presented peptide: reading, translation, cleavage, affinity.

done

A real genome used

The osteosarcoma donation: 628 real peptides, 12,420 candidates. Published results come from it.

done

The criterion revised downwards

91.3% → 47.9%. A measurement by the laboratory against the laboratory itself; it is the lower number that is kept.

done

The per-patient verdicts retrieved

34 targets recognized out of 702 tested, 8 real patients, under an open license.

done

The CEDAR assays read by the bench

156,403 assays, 87,899 documented failures (56.2%), 67,672 distinct epitopes across 468 alleles — now read by the code, and no longer merely declared in a configuration file.

done

The per-patient ranking connected

The reader is written, tested, and called by a measurement tool: the real verdicts now enter a computation.

done

A first measurement on real patients

Made on 11 October 2026, then replicated on three cohorts assembled separately — TESLA, HiTIDE and NCI, 73 evaluable patients in total. Ranking helps, and massively: on NCI, random draw finds 1.2 targets in the top twenty places, the strategies find 43 to 48.

done

A fourth cohort, assembled elsewhere

IMPROVE (Denmark, 2024): 70 patients, 17,520 candidates screened, 467 recognized, no overlap with the first three. Predictions sealed before reading. A non-linear model gains +0.203 targets per patient there — but the lower bound of the interval is +0.000, and the pool is already filtered. Confirmed, not established.

done

The laboratory's most cited fact, withdrawn by the laboratory

For two days, the bench's most striking result was: “a variable that sorts nothing on its own comes 2nd in importance in the model”. Five sealed predictions looked for the mechanism — variable interaction, non-monotonic effect, memorization, top of the list. All five closed. The sixth found it: the importance was measured at the wrong level. Correctly recomputed, it falls from +9.33 to +0.67, and what remains of it contains zero. There was no mechanism to find: there was a computation to check.

done

The question a reader will ask, asked

The four cohorts had always been judged separately. A model trained on three of them and judged on the fourth, never seen, does not transfer: all four folds are negative, and the model does worse than a model trained on randomly drawn labels. So it is not that it learns nothing — it learns something that is false elsewhere. Result published with its caveat: the internal safeguard failed on the smallest cohort, which limits what can be concluded from it. A fifth cohort was therefore integrated to settle the matter (next milestone).

done

A fifth cohort, outside melanoma, read by the bench

IOTech2025 (2025, DOI 10.1016/j.iotech.2025.101062): 19 evaluable patients out of 26, 8,103 candidates tested, 34 recognized, three tumor types out of four outside melanoma. Independent of the first four. Predictions sealed before the first measurement (seal no. 30). Verdict entered in the register: 5 predictions held, 1 refuted — the transfer remains negative, towards this cohort (−0.62) as well as from it (−0.31), and it is the safeguard that is refuted, detailed further down.

done

The formula actually produced, judged on five real cohorts

Until 14 October, the formula a user would obtain had never been confronted with real patients: it required an affinity in nanomolar that none of the five cohorts provides. It was not “awaiting validation”, it was out of reach of its own proof. With the gap filled, it gains +0.233 targets per patient as a mean over the five cohorts against the field's default reflex, without losing on any of the five (clonality has since been removed from the score: its own contribution was negative, −0.063). That does not make an established superiority: read patient by patient, the gain drops to +0.092, with a 95 % paired confidence interval of [−0.024; +0.207] — which contains zero; and on the criterion “at least one target in the top-20” it is 64.71 % versus 64.71 % (10 patients gained, 10 lost): no gain at all.

done

The technical publication

Public repository, verifiable register, method and results — including the bad ones.

not started
Last updated: 14 October 2026, 9:30. This table is maintained by hand. If it stops being up to date, it becomes false — and a displayed progress that no longer moves says more than it seems.

The method

Predictions are sealed
before the computation.

Each prediction is written, timestamped and sealed in a register chained by cryptographic hashes before the computation is launched. Those that are refuted are published like the others.

A CORRECTED RESULT
47.9%
and not 91.3%

An evaluation criterion judged too generous brought this rate down by 43 points. It is the corrected number that is kept.

AND TWO REFUTED IDEAS
0.95
clonality of recognized targets… and of the others

Clonality — the best strategy on invented patients — ends up 4th, 3rd and 4th on the three real cohorts. The measurement says why: recognized targets and the others have the same clonality, and 62 to 73% of candidates are already clonal. There is nothing to tell apart. And the laboratory's composite score does not reliably beat affinity alone: on the largest cohort, the simplest ranking in the world does better.

WHAT THIS RATE SAYS

“The panel contains at least one relevant target”

And not “a vaccine that works”. That nuance is the whole gap between a test bench and a promise.

Declaring a path is not reading a file;
downloading is not connecting.

Written on 11 October while two sources had been retrieved without being read. Since 12 October, 01:11, all three are — and the sentence stays, because it was true.

A variable that equals 0.95 for everyone
cannot sort anything.

A LAW THAT HOLDS ON REAL DATA
≈ 34
purity × reads, on a real genome

Measured on invented patients, the rule says that only the product purity × number of reads matters, and that beyond about 8 more reads add nothing. On the real osteosarcoma genome: 23% tumor × 148 reads ≈ 34. Diluted, but read more than enough. First time a result from the simulated bench is confronted with real data and holds.

AN ANSWER CORRECTED THE SAME EVENING
16
mutations, where thousands were announced

A reference clonal inference tool was to be plugged into this genome. Once checked: the 12,420 lines of the file are epitopes, coming from only sixteen mutations — and the copy number is missing. The tool is set aside. Claiming that a tool is applicable without having opened the file is the same shortcut as displaying “connected” because a path is declared.

A number you cannot explain
first deserves a check of how it was computed.

Five doors, and the sixth

On 12 October, the bench produces a troubling fact: one variable — clonality, the share of tumor cells that carry a mutation — sorts nothing when taken alone (it separates good targets from bad ones as poorly as a coin tossed in the air), and yet comes second when we measure what the model owes it. For two days, it is the laboratory's most cited result. Five sealed predictions looked for the reason.

WHAT WE LOOKED FOR

Four explanations, four closures

An interaction between variables? No: a model that is forbidden from crossing two columns reproduces the gain identically.
A “bell-shaped” effect that the simple measure would not see? The bell exists on one cohort — and is found on no other.
Memorization rather than understanding? No: redone on patients never seen, the importance holds.
An effect concentrated at the top of the ranking, where the decision is made? True on two cohorts, false on the one that carried the number.

WHAT WE FOUND
+0.67
and not +9.33

To know what a variable contributes, we scramble it and look at what the ranking loses. But the ranking is done patient by patient, whereas the scrambling shuffled the values across patients. And this variable describes the sample: only 34% of its variation plays out within a patient. Scrambling it across patients therefore destroyed no sorting information: it moved the whole patient to where the model did not expect it. The measured drop was the price of that shift.

AND THE FINAL ARBITER
0
is in the interval

What remains is the only measure that depends on no convention: remove the variable, retrain, and count. The gain goes from +0.203 to +0.138 target per patient: the variable contributes +0.066. Then we ask whether this remainder holds — by replaying the measure on resamples of the 61 patients. Answer: from −0.09 to +0.23, and one resample in five gives a negative contribution. On this cohort, the contribution of this variable is not distinguishable from zero.

A gain measured at home says nothing about what it is worth elsewhere
— and can hide that elsewhere, it does harm.

And the measure that could bring the method down

Until now, each cohort was judged at home. That is the most favorable measure, and it is not the one that counts: the real question is “does a model learned elsewhere work here?”. Four trials, each learning on three cohorts and judged on the fourth, never seen. The columns are converted to internal ranks so that the scales are comparable — the version most favorable to transfer.

THE TRANSFER
0
positive trials out of 4

All four are negative, from −0.22 to −1.16 target per patient: a model learned elsewhere ranks worse than binding affinity alone, that is, worse than the simplest reflex in the field.

AND THAT IS NOT THE WORST

It does worse than chance

The same trial, with labels drawn at random, gives −0.01 where the real model gives −0.41. Across the four cohorts, learning on real data from elsewhere is more harmful than learning on noise. So it does not learn “nothing”: it learns a regularity that is not true elsewhere.

THE CAVEAT, ANNOUNCED BEFORE MEASUREMENT

The safeguard failed

The seal required that, before talking about transfer, the model at least win at home in all four cohorts. On the smallest — 9 patients — it also loses at home. Part of the deficit may therefore come from the reduction to nine columns, and not from transfer. No firm conclusion can be drawn, and that is said here rather than omitted.

Correction, the same evening. For twenty minutes this page claimed that “there is no fifth public cohort”. That was too strong: a 2025 cohort covering four tumor types (melanoma, mesothelioma, triple-negative breast cancer, urothelial cancer) does carry a per-patient screen with its negatives — 19 evaluable patients, 34 recognized targets out of 8,103 candidates. It does, however, contain no clonality measurement, the variable at the center of the previous sections. The exact statement is therefore: there is no public cohort carrying both a per-patient screen and a clonality measurement. The research conclusion does not change; the sentence that framed it was false, and that is written here rather than silently rewritten.

The fifth trial: a cohort that is not melanoma

The caveat above left two possible causes: a regularity that is false elsewhere, or a model impoverished by the reduction to nine common columns. A new prediction was sealed before the measurement (no. 30): redo the same trial with four columns, and add the fifth cohort, in both directions — the four others towards it, and it alone towards each of the four.

THE NUMBER OF COLUMNS
+0.20
target per patient of difference

With four columns instead of nine, the mean transfer goes from −0.73 to −0.53 target per patient. It remains negative: the lack of columns does not explain the failure (announced threshold: ±0.40).

TOWARDS THE FIFTH, AND FROM IT
−0.62
target per patient, towards IOTech2025

Learned on the four others, the model ranks worse than binding affinity alone on the 19 patients of the fifth (from −0.74 to −0.58 depending on the seed). In the other direction, learned on it alone, it loses on average −0.31 on the four others. Across the five folds, the mean is −0.57; no fold is positive on average (on IMPROVE, the best seed reaches +0.03).

WHAT LIMITS ITS READING

Three caveats

The safeguard exceeds its threshold: on shuffled labels, the worst fold reaches +0.21 against an announced ceiling of +0.20. With four columns, the model does not beat binding affinity even at home on three cohorts out of five. And the ranges given here are spreads between seeds, not yet intervals over patients.

Provisional, and said as such. These numbers come from the first run, made after seal no. 30; its verdict has since been recorded in the register: five criteria met out of six. What can already be written: a cohort that neither of the two previous pipelines produced, and which goes beyond melanoma, does not contradict the failure of transfer. It says nothing about clonality, which it does not measure.
Why tell this rather than erase it. The five predictions, including those that were wrong, are sealed in the public registry with their date — they can be read one by one. Of the six criteria of the sixth, three were refuted, one of them by our own safeguard: the control went outside its bounds, which makes the small values of this measure unreadable — and that is precisely why the conclusion rests on removal, which depends on no control. A laboratory that publishes only what works lets no one know what it is worth.

Six possible explanations for this failure. All six have been closed.

A negative result is only worth something if we know why. Six plausible causes were therefore measured one by one, rather than assumed: did the model lack columns? was a variable oriented backwards from one cohort to another? were the cohorts too different in target frequency? were there simply not enough patients? None of the six explains the failure.

THE DOOR WE HOPED FOR MOST
flat
the learning curve

“Not enough data” is the most comfortable explanation. It is false here: varying the number of training patients from 5 to 56, transfer does not improve — −0.24 with 5 patients, −0.36 with 56. A curve that stays flat says that more data would fix nothing.

A VARIABLE BACKWARDS?
0.04 / 0.63
the same column, two cohorts

A column bears the same name on both sides and does not measure the same thing: a rank here, a score there. Its sorting ability is 0.04 on one cohort and 0.63 on the other — the inverse of each other. Once corrected, transfer gains only 4%: real, but marginal.

WHAT REMAINS, AND IS STRUCTURAL
×144
difference in target frequency

From one cohort to another, the proportion of candidates that are true targets ranges from 0.032% to 4.62%, and the number of candidates to sort per patient from 92 to 5,674. These five cohorts are not five samples of the same world: they do not ask the same question.

And one measurement went against intuition. If the frequency gap explained the failure, the closest pairs of cohorts should transfer best. It is the opposite that is measured: close pairs score −0.88, distant pairs −0.50. The most natural hypothesis is therefore not only closed, it is contradicted in the opposite direction.
What this diagnosis teaches in concrete terms. A model that learns its weights on one cohort does not transfer to another. But the formula with fixed weights — the one described below, which learns nothing from any cohort — holds on all five, without losing a single one. When datasets do not answer the same question, what is needed is not a cleverer model: it is a rule that depends on none of them.

The night the laboratory withdrew three quarters of its most cited result

This laboratory's most quoted result said: +13.87 points gained by taking into account a target's clonality — the share of tumor cells that carry it. That number is exact. It is reproducible, its interval excludes zero, and the checker recomputes it on every pass. What has just been measured is not its value, it is its scope.

For the simulation that produces it contained a hard-coded rule: below 0.9 clonality, a target is never the right one. In other words, the test bench postulated what the measurement claimed to establish. A prediction was therefore sealed before rerunning the simulation without this rule (no. 32), with the same recipe and the same seed: only the immunogenicity condition changes.

WHAT REMAINS OF IT
−74.3%
of the gain disappears

The gain goes from +13.87 points to +3.57 as soon as the simulation stops guaranteeing in advance that a target is clonal. The drop announced before measurement was at least 40%: it reaches 74.3%.

AND THE QUARTER THAT REMAINS
[−0.41, +7.80]
the interval contains zero

The remaining +3.57 is no longer distinguishable from zero. On the cohorts of real patients, the measured contribution ranges from −0.063 to +0.066 target per patient: never different from zero either, by three independent protocols.

THE COHORT IS RECALIBRATED, NOT BROKEN
0.96
binding affinity keeps its power

Two locks set in advance attest to it: 97 patients now carry subclonal targets, where the old convention forbade all of them; and binding affinity retains a sorting ability of 0.9649. The control, with shuffled clonality, falls to 0.4909 — chance.

One criterion was refuted, by 0.0006. Of the six set, five are met. The sixth predicted that clonality's sorting ability would fall to at most 0.60; it is measured at 0.6006. The gap is negligible, the prediction is refuted all the same, and it is recorded as such: a threshold moved after the fact is no longer a threshold.
This flaw was not hidden: it was written down. The laboratory's code had documented this rule since 27 September, with this sentence: “a test bench that guarantees in advance the value of a component does not measure it, it postulates it”. The option to remove it already existed — switched off by default, so as not to make the cohorts incomparable with one another. So this is not an error discovered, it is an error known, documented, and left active for seventeen days. The nine published claims that depend on it keep their value, unchanged, and now carry a note of what limits their scope.

And the same night: what the laboratory produces finally beats the field's reference

The formula that would actually designate targets — the one a user would get — had never been confronted with the cohorts of real patients. For a reason that speaks volumes: it required a binding affinity measure in nanomolar, which none of the five cohorts provides. So it was not merely unvalidated: it was unvalidatable. The cohorts give percentile ranks — which the IEDB precisely recommends, because a rank is comparable from one HLA allele to another when a concentration is not.

AGAINST BINDING AFFINITY ALONE
+0.233
target per patient, mean over the five cohorts

None of the five real cohorts is a losing one. But the gap is not established: read patient by patient it drops to +0.092, with a 95 % paired interval of [−0.024; +0.207], which contains zero; and on “at least one target in the top-20” the result is 64.71 % versus 64.71 % — 10 patients gained, 10 lost: no gain at all.

CLONALITY HAS BEEN REMOVED
−0.063
the net contribution it had

The formula granted it 20 points out of 100, as much as HLA binding, for a negative net contribution: removing it improved the score. It has weighed zero ever since, and the figure opposite is the one without it. What makes the gain is the gene's expression.

THE TWO GUARDS

Six criteria out of six

On shuffled labels, the worst of the five folds stays at +0.105 against an announced ceiling of +0.20 — the control holds, whereas it had failed the day before. And a code lock checks that the binding component reproduces exactly the ranking of binding affinity alone: measured difference, 0.000000.

Why these two results go together. The first removes a component that the bench had granted itself; the second shows that what remains holds all the same, on five cohorts assembled by other teams, with other pipelines. A laboratory that could only publish its gains would let no one know what it is worth: the predictions are sealed one by one, with their date, their hash, and the criteria they lost.

And the test bench itself: it believed its predictor three times more precise than it is

This laboratory's strongest variable is the predicted binding affinity of a peptide for an HLA molecule. The simulator therefore places noise between the true affinity and the one the predictor announces: a single line, ERREUR_PREDICTEUR = 0,50 in log10, i.e. a factor of 3.2. It has been there since day one, and no measurement had ever established it. All of the bench's realism on its master variable rested on a number written by hand.

A prediction was therefore sealed (no. 33) before the first confrontation, against 5,115 affinities measured in the laboratory and not computed by another model: 6,349 published measurements, grouped by peptide–allele pair, with the “greater than” and “less than” bounds set aside — a bound is not a value.

THE REAL ERROR
1.019
against 0.50 assumed

The standard deviation of the residuals is 1.019 in log10, i.e. a factor of 10.5, where the bench assumes 0.50, a factor of 3.2. The criterion announced “at least 0.45”.

BUT IT REALLY SORTS
0.69
rank correlation

Lock set in advance: with no link between predicted and measured, this standard deviation would measure not an error but an absence of link. It is 0.686. And on affinities shuffled at random, the error rises to 1.723: the control holds.

AND IT IS RANDOM, NOT A SHIFT
−0.16
median bias

The predictor announces affinities barely better than measured, but most of its error is noise — exactly the form the simulator assumes. Six criteria out of six are met, including the one that announced the flaw.

And on the peptides that really decide, the error does not drop. One might hope that the predictor is mostly wrong about uninteresting candidates. Measured on the 2,832 pairs whose measured affinity is good — below 500 nM, the usual threshold, an affinity being all the better as its concentration is low — the error is still 0.816, a factor of 6.5 against 3.2 assumed. Yet it is these peptides that decide the sorting: the predictor's error on a candidate that will never be retained costs nothing. Same caveat as below: this number includes experimental error, so it is an upper bound.
What this 1.019 does not say, and it must be read before the rest. It includes experimental error and the heterogeneity of protocols: depending on the assay method, the median bias ranges from −1.84 to +1.48. In other words, “IC50” does not quite designate the same quantity from one laboratory to another. This 1.019 is therefore an upper bound on the predictor's error — while the disagreement between eight predictors, which largely train on the same data, is a lower bound on it (0.257). The bench's 0.50 lies within this interval, closer to the bottom than to the top. The correct statement is therefore not “the value is wrong” but: we have gone from no measurement to a bracket, and this value is more likely underestimated than overestimated.
A criterion met that explains nothing, and it was announced as the most fragile of the six. On the 279 pairs published since 2017, hence after the predictor was trained, the error rises to 1.496 (+0.476): the expected trace of a model that has already seen its control data. But at constant assay method, the gap reverses — radioactivity since 2017 σ = 1.44 on 64 pairs, fluorescence since 2017 σ = 0.75 on 62. With sample sizes of sixty, training leakage and the change of protocol cannot be separated. The criterion is met; it does not demonstrate the leakage, and nothing written here says otherwise.
Why a seal met from start to finish is not a victory. A fully met seal does not say that the right value has been found: it says that the predictions were correct, including the one that announced a flaw in the bench. And the measurement first corrected an error made here the day before: a spread between eight predictors had been compared with the standard deviation of a single one — two different quantities under the same word, and the conclusion went in the wrong direction. A disagreement between models that share their training data underestimates their error: it does not measure it.

This is also why the progress shown above does not go up: this seal crosses no milestone, it measures the instrument and not the road. A progress counter that gained a point every time the laboratory found a flaw in itself would end up rewarding the discovery of flaws — and congratulating oneself on one's bad news is no more honest than hiding it, only more devious.

And the component that held things back: the twenty points that must be given back

The formula put into production grants twenty points out of a hundred to a target's clonality — as much as to its HLA binding. Four measurements already said that these points cost: nothing out of sample, nothing in transfer, −0.063 target per patient on the five real cohorts. One number was missing: what they are worth in a simulation that no longer postulates what it measures.

A prediction was therefore sealed (no. 34), then judged on an independent replicate of the recalibrated cohort — a dataset that did not exist at the second the prediction was made, and whose absence and then birth a second machine recorded, forty-four minutes later. A preregistration whose data already exist is worth only the word of the person who makes it.

WHAT THESE TWENTY POINTS COST
+9.2
points gained by removing them

Interval [+6.7, +11.7]: zero is excluded. The prediction announced “removing clonality must not cost more than three points”. Not only does it cost nothing: it pays off.

THE PRODUCTION SCORE AGAINST THE REFERENCE
−5.7
against binding affinity alone

On this recalibrated bench, the formula with its twenty points of clonality does worse than the field's reflex, interval [−9.7, −1.5], zero excluded. Both locks hold: binding affinity keeps 0.964 of sorting power, clonality falls to 0.605.

A PREDICTION REFUTED FROM ABOVE

Four criteria out of six

The decisive criterion predicted that the gap would be indistinguishable from zero. It is refuted: the gap is clear. A prediction can be wrong because reality is more clear-cut than announced, and it is recorded as a refutation all the same.

The second refutation comes from a badly built control, and saying so is more useful than hiding it. This control required the production formula to beat random draw by twenty points. Yet no strategy exceeds +18.4 on this cohort: the threshold was not strict, it was closed. And it took as its reading condition the very thing being tested, since the production formula contains the component in question: it therefore could not distinguish an unusable bench from a confirmed hypothesis. The two sound controls, for their part, show that the bench sorts perfectly: binding affinity alone beats chance by +9.6, the formula without clonality by +13.1. This criterion is recorded as ill-posed — which is not the same thing as a refutation. A control that depends on the tested hypothesis cannot distinguish a broken bench from a confirmed hypothesis.
And the check that prevents self-congratulation too soon. A criterion that settles for “zero is in the interval” rewards imprecision: a wide enough interval makes it hold without proving anything. The width was therefore recorded before the replicate existed, on the previous cohort: 5.07 points. Measured on the replicate: 5.07 points. So the decision does not come from a lack of precision — and this comparison point was fixed in advance, not chosen after the fact.
Two worlds that seemed to disagree end up concurring. On real patients, removing clonality gains +0.063 target per patient; on a recalibrated simulated bench, +9.2 points of success. These are neither the same scale nor the same world, and it must be said every time: but four independent measurements, in two worlds, point in the same direction. What follows is no longer a measurement, it is a decision: removing these twenty points would change the lists of targets this laboratory would produce, and would make its future comparisons incomparable with the old ones. It is not taken here.

And for the first time, a measurement on what happened to patients

Everything above concerns targets: recognized or not by lymphocytes, in the laboratory. Nothing concerned what became of the patients. Two sealed predictions took that step, on a cohort of 26 people treated with anti-PD-1 whose biopsies and outcomes have been published since 2016.

The hypothesis: if a tumor has switched off the machinery that shows its fragments to the immune system, no well-chosen target will change anything. This machinery can be read in the expression of seven genes.

SEPARATING RESPONDERS — NOT REPLICATED
0.728
on 26 patients · 0.541 on 65

On the initial cohort: interval [0.52, 0.91], and only 2.5% of randomly drawn gene sets do as well.

⛔ But the measurement did not replicate. Redone on a second cohort of 65 patients (seal no. 42, set before looking), the sorting ability falls to 0.541 [0.33, 0.75] — that is chance. And 30% of sets of seven genes drawn at random from 22,187 do as well or better, where they were only 2.5%. Housekeeping genes, for their part, separate better there (0.585) than the signature.

ORDERING SURVIVAL
0.613
but 10.5% of chance does as well

On 186 comparable pairs and 12 observed deaths. A set of seven genes drawn at random orders survival as well in one case in ten: at this sample size, this result is an indication, not a demonstration.

AND WHAT DOES BETTER THAN US
0.788
the physician's judgement

The clinical assessment of response orders survival better than the signature, by 0.175. This measurement therefore replaces nothing: it says whether a target has a chance of being seen, not what will happen to the person.

This laboratory's first clinical result did not replicate. It had been published here on the very day it was measured, with its interval and its control. The next day — a few hours later, in fact — a cohort of 65 patients instead of 26 finds nothing: 0.541 against 0.728, and a random control that goes from 2.5% to 30%. The sealed prediction said, word for word and before the measurement: “if the signature separates nothing on 65 patients, the first result becomes a 26-patient result that a larger cohort does not confirm — and it will have to be written as strongly as if it had held.” That is the case, and it is written here, in the same card as the number it corrects.

✅ What remains true. The two other measurements concern the first cohort and describe it correctly: there the signature beats each of its seven genes taken separately, B2M comes only fifth, and the physician's judgement orders survival better than it does. These are facts about that cohort, and they remain true of it. What falls is the generalization.

⚠️ And one thing we will not say. Under treatment, the sorting ability rises a little (0.606). It would be tempting to make it a lead: we will not. The two groups share patients, so no interval can be computed on this difference. It was declared “observation, not test” in the seal, before the measurement, and it remains so.

What these two numbers allow us to say, and nothing more. Twenty-six patients, twelve deaths: that is few, and both intervals show it. The first result is clear — switched-off presentation machinery goes with an absence of response, and chance imitates it in only 2.5% of cases. The second is much less so, and it is published with the number that weakens it in the same sentence. ⛔ Neither of these two measurements says what should be done for a patient, neither was made on a patient currently under care, and neither replaces the opinion of a care team.
A connected dataset that nobody had called on. These two measurements were possible the day before: the cohort was loaded, readable, documented — and no computation asked for it. So it slept for twenty-four hours within reach. A connected dataset that no measurement calls on is not a resource, it is an intention.

What remains between a good target and a patient who recovers

Everything above measures a single thing: is the right target on the list? It is necessary, and it is far from sufficient. Three conditions then decide, and none was instrumented: that the body's defences can learn the target — that is the role of a vaccine; that the tumor does not hide it; that all its parts carry it. They have been since 14 October 2026, and the result is none of the three.

SHOW — MEASURABLE, AND USEFUL
3.054×
difference between tumors

The machinery that shows fragments to the immune system varies by a factor of 3.054 across 109 samples and 4.0414 across 28, in two independent cohorts. Current sorting ignores it entirely.

CARRY EVERYWHERE — MEASURABLE, AND USELESS
0.5694
at best, across four cohorts

Clonality alone does not distinguish the recognized targets: HiTIDE 0.5694 · IMPROVE 0.4579 · NCI 0.5463 · TESLA 0.4458. Two cohorts below 0.5, that is, worse than chance. This is the fifth measurement pointing in this direction.

LEARN — NOT MEASURABLE
100%
the figure that reveals the trap

Checked against the database of real assays, our recognized targets react 100% of the time across 456 cases. Such a rate does not exist in biology: it reveals that the ground truth and the prediction come from the same observation.

And the result is their overlap: zero. A chain of conditions cannot be measured by measuring its links one by one — it is measured on the patients who pass through all of them. On the public cohorts connected here: 134 patients carry both tested candidates and their clonality, and 0 carry both tested candidates and the expression of the presentation machinery. So 0 patients in the world, in these data, carry all three.

⛔ The success rate of the complete chain is therefore not “low”: it is undefined, and saying so is more useful than estimating it. This laboratory used to write that it “lacks a partner laboratory”. The measurement makes that sentence precise: what is missing is a cohort carrying, on the same people, candidates tested one by one, their clonal fraction, and the expression of the presentation pathway.

⚠️ And one measurement was wrong three times before it was right. The first version of the “show” gate defined “switched off” by a quartile of the cohort: it therefore returned one minus one quarter by construction, without ever reading the data — unmasked by its own control, which returned exactly the same value. The second set a threshold that nothing could satisfy. The third averaged a chain: a total loss of the B2M link lowered the score by only 14%, whereas it switches off presentation entirely. These three versions are kept in the code with their figures, so that nobody redoes them.

The thirteen measurements in this section carry a recipe name (portes:…) and are recomputed with a single command: python outils/mesurer_les_portes.py. A published figure that no recipe recomputes is a figure one merely believes.

A lead closed, and what it took to close it

A signal had been spotted in September: candidates whose non-mutated version is also presented by the cell seemed to be better targets. The idea made sense, and so did the figure: these candidates are 9.7 times more often true targets than the others, in four cohorts out of four. It took three sealed predictions to establish that this signal is of no use.

THE SIGNAL EXISTS
9.7×
more often true targets

Across 1,232 marked candidates, in four cohorts out of four. And the control holds: a randomly drawn mark gives 0.72, that is, nothing. The signal is therefore real.

IT DESERVES NO WEIGHT
0
chosen five times out of five

Put in competition as a component of the score, the optimal weight chosen by cross-validation is zero — five times out of five. ⚠️ This seal is recorded as ill-posed: its lock required a non-zero weight in order to be readable, and that is precisely what was refuted.

AND NO PER-PATIENT RULE
−25
targets lost in total

Moving these candidates to the top of the list, patient by patient: 6 patients gain a target, 27 lose one. 🚧 And the control finishes off the lead: a randomly drawn mark saves 4.5. The gain for the six came from the rarity of the move, not from what the mark designates.

Three independent paths, a single conclusion. The signal exists, it deserves no weight in the score, and it supports no per-patient sorting rule. Each of these three answers required a prediction sealed in advance, with its criteria and its control; none would have sufficed on its own.

⭐ And the control of the third seal is the most instructive of the series. A mark placed at random saves almost as many patients as the real one: 4.5 versus 6. In other words, what made these six patients win was not the information carried by the mark, but the mere fact of rarely shaking up a ranking that was already good. Without this control, “six patients saved” would have made a headline, and one more false lead.

A spectacular case is not a sample: looking for what explains it is useful, drawing conclusions from it is the trap it sets. This lead started from a single patient whose sole target was striking. It cost three preregistrations, and that is the right price: a lead closed properly does not get reopened every six months.

Choosing patients on a failure manufactures almost one target per patient

When a ranking rule fails in some patients, it is tempting to look at those patients and try something else on them. It is the most natural move in research, and nobody escapes it. We measured what this move manufactures on its own, without any method being better.

WHAT THE SELECTION MANUFACTURES
+0.93
target per patient, pure mirage

On the 55 patients where our reference rule catches nothing, a competing rule gains +0.25 target per patient. On the 153 patients, the same rule loses 0.67. The difference: +0.9277. 🚧 And the control that makes this figure credible: 55 patients drawn at random manufacture only −0.0086, that is, nothing.

AND THE RULE IS BAD
−103
targets lost in all

The same competing rule, judged on all patients, destroys 67 of the 98 patients who succeed today. It is therefore plainly bad — and on the patients chosen on failure alone, it looked good.

THE REFUTED PREDICTION
48
instead of “at least 50”

We had sealed five predictions. Four held. The fifth: we thought the failure was clear-cut — the best target pushed far down, median rank at least 50. It is 48, with a range from 21 to 1,314. Failure is often a matter of little.

What this measurement says, and which is not about biology. The other results on this page speak of tumors and lymphocytes. This one speaks of a way of working: looking at the cases that failed in order to try another method on them. This move manufactures, on its own and with no merit whatsoever, nearly one target per patient. That is enough to make a method that loses 103 targets look excellent.

⚠️ And one thing we did NOT measure. The refuted prediction opens a lead: since failure is a matter of little, widening the poster from 20 to 50 places would save about half of these 55 patients. But the 67 patients destroyed by the competing rule are a reminder that a widening is paid for elsewhere — and we have not measured that cost. So this is not a result: it is the next question.

A target that is not nine residues long is found a third less often

The fragments our rules rank are not all the same length. Most known targets are nine amino acids long — that is the size presentation molecules carry most readily. We measured what this length changes, on the 153 patients of our five cohorts.

WHAT LENGTH COSTS
18.0%
versus 28.6% for nine-mers

Nine-residue targets are recovered in 28.6% of cases (440 targets). Those of any other length, in 18.0% (239 targets). A gap of 10.6 points, and 239 true targets are on the wrong side.

⭐ THE QUESTION WE HAD ASKED WRONGLY
×8
between the wrong and the right measurement

First question: do the top twenty places contain more nine-residue fragments than the pool? Answer +0.4930, spectacular — and worthless: true targets are mostly nine-residue fragments, so a ranking that keeps many of them could simply be right. Compared with the right reference point — the targets themselves — the excess falls to +0.0605.

AND OUR HYPOTHESIS IS WRONG
0.0287
in failing patients, versus 0.0692 at random

We thought part of the failure was explained by this narrowing. That is wrong: the phenomenon is weaker in the patients where the rule fails than in randomly drawn patients. It costs targets; it does not explain those failures.

The lesson is not the figure, it is the question. The +0.4930 of the first attempt would have made a good headline. It compared the top twenty places with the pool, when it should have compared them with the targets: a ranking that keeps many nine-residue fragments is not biased, it recognizes a reality. The right reference point divides the result by eight. We publish both, because the first question is the one a reader would also ask.

⚠️ And a limitation we declare rather than leave to be discovered. One of the five cohorts mixes two types of sample — blood and tumor cells — without distinguishing them. This concerns 19 trees out of 153: too few to overturn the 440 versus 239, enough for it to be written here.

⛔ What we do not know. If this narrowing does not explain the failures, then their cause remains unknown. We have none: this is the second hypothesis we have discarded after sealing it, and it leaves the question open.

Our best success rate is the one we deserve least

Our patients do not all have the same number of recognized targets. We find at least one target in 44.8% of those who have only one, and in 81.8% of those who have four or more. Read this way, it gives the impression that our method serves target-poor patients badly. It is the opposite. We computed what a randomly drawn 20-place poster would achieve on these same patients.

Recognized targets
in the patient
Patients We find
at least one target
A random poster
succeeds
Own contribution
15844.8%7.7% +37.2 points
22560.0%12.0% +48.0 points
31580.0%22.2% +57.8 points
4 or more5581.8%53.3% +28.5 points
all15364.1%26.2% +37.8 points
⭐ WHAT CHANCE ALREADY ACHIEVES
53.3%
in patients with four or more targets

In these patients, a randomly drawn poster already catches a target more than one time in two — because there are more right answers to find. Our 81.8%, the laboratory's best raw rate, is therefore the one where our sorting contributes the least. At three targets, for an almost identical observed rate (80.0%), the contribution is twice as large.

THE CONTRIBUTION SHRINKS AS THE RATE RISES
−0.195
between two targets and four or more

This is the heart of the result: the two columns move in opposite directions. The observed rate rises from 60.0% to 81.8%, the contribution falls from +0.480 to +0.285. Reading the rates alone leads to the opposite conclusion from the measurement.

THE REFUTED PREDICTION — IN OUR FAVOUR
+0.285
where we had bet “at most +0.20”

Four predictions sealed before the measurement, three held. The fourth is refuted, and in the direction that is favorable to us: we had predicted that the contribution in target-rich patients would fall below +0.20. It is +0.285. We had underestimated ourselves. This contribution is the weakest of all the strata; it is not negligible, and we will not write it up as such.

A success rate cannot be judged without the one a random draw would achieve in its place. This is true of our figures as of those others publish: a raw rate, on its own, does not say whether a method did the work or whether the problem was easy.

⚠️ Two figures look alike and do not measure the same thing. We also publish, at one target, a contribution of +0.3716 on the share of targets caught, which falls to +0.1376 at four or more. Here, at one target, the contribution on the share of patients served is the same +0.3716, and falls to +0.2849. The equality on the left is nothing remarkable: in a patient who has only one target, “what share of their targets” and “do they have at least one” are the same question. These are indeed two distinct quantities, and neither corrects the other.

⛔ What this table does not support. The column with the strongest contribution (+57.8 points) rests on only 15 patients, and the one at three targets on 15 as well: the fine ranking of the middle strata is not established. What is established is the direction of the slope between the two ends — 58 patients on one side, 55 on the other.

Do we fail on certain cancers? We cannot know

This is the question a physician asks first, and we answer it with a measured admission rather than with silence. Across our six tumor groups, the difference in success reaches half a target per patient (+0.5243) — and randomly drawn groups produce 98% of it (+0.5140, i.e. 0.9803 of the share explained by noise). As long as we have 10 to 29 patients per cancer, this question will remain beyond our reach.

THE SHARE EXPLAINED BY NOISE
98%
of the difference between cancers

We redid the same computation by reassigning the organ labels at random within each cohort. Groups with no meaning at all produce a difference of +0.5140, versus +0.5243 for the real ones. There is nothing left to interpret.

THE SAME CANCER, THREE TIMES
0.0370
… 0.3943
melanoma, depending on the cohort

Melanoma appears in three of our groups, with contributions of +0.3943 (28 patients), +0.2145 (10) and +0.0370 (23). Same organ, a tenfold difference. ⚠️ But these three groups differ not only by cohort: the treatment received and the way recognition is measured also change. So we do not know what is speaking — only that it is not the organ alone.

THE CRITERION MET IS THE ONE THAT EMBARRASSES US
4 / 4
predictions held

This seal was set knowing that it had stakes in both directions: meeting the main criterion meant demonstrating our own blindness. It is met. The question proposed at the outset — “does the tumor type change the result?” — had been discarded before sealing: at these sample sizes, it could conclude nothing.

⛔ What we will not write: “failure is the same everywhere”. A test that rejects nothing on 16 patients demonstrates no equality. Absence of signal is not a signal of absence; and a result that does not conclude does not become reassuring because it is phrased the other way round.

⚠️ And our “six tumor groups” are not six cancers. Three of them are melanoma under three different cohort labels (61 trees out of 153), and a fourth is a so-called “basket” trial that gathers various cancers under a single line. We publish these groups as the sources name them, without merging or re-splitting them: re-splitting after seeing the results would be exactly the move we measured above, and quantified at nearly one target per patient of pure mirage.

➡️ What it would take to answer. Single-cancer cohorts, of the order of a hundred patients each, with recognition measured in the same way. We have none. This is one of the reasons this laboratory is looking for data rather than conclusions.

The difference we thought we saw between our patients came from the ceiling

Since chance does not have the same odds in every patient (see just above), we asked whether our rule behaves differently where chance often succeeded and where it had almost no chance. On the face of it the difference is clear-cut: the contribution is +0.6050 in the 57 patients where chance succeeded only 0.9% of the time, and +0.2846 in the 65 where it already succeeded 54.6% of the time. This difference is misleading, and it is so with certainty.

⭐ RIGGED BY THE CEILING
0.454
the maximum achievable, not a result

In the group where chance already succeeds 54.6% of the time, the contribution cannot exceed 0.454: that is all there is left to gain. In the one where chance succeeds only 0.9% of the time, it can reach 0.991. “The contribution decreases as chance's odds increase” is therefore guaranteed in advance by arithmetic, and says nothing about the method.

RELATIVE TO WHAT WAS LEFT TO GAIN
−0.045
difference, instead of +0.320

The quantity that makes the groups comparable is the share of the available margin that the rule took. It is +0.6101 in patients with poor odds and +0.6550 in the others: the rule takes roughly the same share of what there was to take everywhere, and even a little more where chance was good.

THE OBSERVATION WE CANNOT EXPLAIN
+0.184
the middle stratum, 31 patients

In between, patients in whom chance had a 13.2% chance fall to +0.1844 while the two other groups are at +0.61 and +0.66. We do not know why. We publish it without explaining it, and without counting it as a result: 31 patients, no sealed prediction on it.

What this result is, and what it is not. It concerns our way of reading, not the disease: a comparison that looked clear-cut was measuring something other than what we believed. It is the same family of error as the selection bias further up this page.

⛔ And we will not write that our failures are “of the same nature” everywhere. The −0.045 is not a confidence interval: it is a difference measured on 57, 31 and 64 patients, checked against a tolerance of ±0.25 set before the measurement. Meeting it means “we saw no difference”, never “there is none” — exactly as for tumor types, two results above. The cause of our failures remains unknown.

⚠️ Two clarifications we could be blamed for keeping quiet. First, the two columns do not have the same sample size: a patient in whom chance would succeed with certainty has no margin left, and is excluded from the ratio rather than making it impossible — the raw contribution therefore covers 65 patients and the margin share 64. This is a patient whose catalog contained only 17 candidates for a poster of 20 places: there was nothing to sort in their case. Second, this result has no randomly drawn control, unlike the others on this page: its check is arithmetical — the ceiling is not a hypothesis, it is a calculation.

The hashes, for anyone who wants to check. Each prediction is sealed before the measurement, and its SHA-256 hash is published on the day it is set. A hash does not reveal its content: it only proves that a text existed beforehand, and that it has not been rewritten since.
prediction no. 31 · 2026-10-13 23:59:57
c04048fd2aa94ff7b922cb42f662e7e8d5605d26b48429f79dd0a155220388c7
prediction no. 32 · 2026-10-14 00:20:35
7ef3e2c8a68356c0ede46fd93683391279fb3dd1b98669437290d4f5f5a9492e
prediction no. 33 · 2026-10-14 12:38:36
baf89f04400cb6b2f6612890149cbbbf99bc2903ecae8571de0f8e96d420511f
prediction no. 34 · 2026-10-14 13:16:11
bed717424ad46fea0222cf401ee8b14fdcfae3f2a5133569dc756ba4170fde74
prediction no. 37 · 2026-10-14 15:09:27
0ed78a044f4c22046cd3d465fb9d3b56d863ec1bdb6781f4804b36f644e8b562
prediction no. 38 · 2026-10-14 15:28:00
f106c7c3d6119cfc768ac003b26167539014c3f47349b01b58b43312ac083e66
prediction no. 42 · 2026-10-14 18:30:58
49ff69310e7a7f0c93441a94d3aeb64156b4a06eb175ab86b1fada368c5e5823
prediction no. 43 · 2026-10-14 19:39:22
087cec53759d10e90825a6f3bcbc138c2b3bdb6637c276ca364b2c2048ac50e1
prediction no. 44 · 2026-10-14 20:06:54
b82adffb6b7b12d175e9cf6b183ca2ed35b75a2863a2c1141ed458bbb500fdfb
prediction no. 45 · 2026-10-14 21:51:26
88d0ace1fb18b14850a8be0a03844e28aa7438f1db6aa537035131b6bc0d100d
prediction no. 46 · 2026-10-14 22:09:32
82def4dcc8004a09a13deb21cc0fd6f243b002292b0b0752bafa0311e96a16c2
priority seal · 242 files · content root
397d0deb03105c8d7d3813924bb33a51abd98ede35a91ea92c4167b552f81094
the same item, anchored in Bitcoin on 14/10 · blocks 971315, 971319, 971354, 971357
14752a5d35a379b39904d0c440ecd8c6f03e627037bf08df612f3780847d8dcc

Only the hash leaves the machine: never a file, never any patient data. This item is anchored in the Bitcoin chain: its four attestations have been collected, and contesting its date would amount to rewriting Bitcoin. The two items of 11 October are too. A more recent item, sealed on 14 October at 07:55 UTC, has been submitted to the same calendars and has not yet matured: it is therefore filed, not proven, and that is written as such.

The same hashes are filed with a third party, with its own dated history: github.com/Damienchapus/complexitylab-public-hashes. For each prediction, it lists its date, its hash and the number of criteria met — never its title, which would describe the hypothesis under way. The 65 predictions can be read one by one.

Follow

There is nothing
to announce.

The measurements are under way. A mailing list will be opened when there are results to publish; it will be addressed to anyone interested in the method, and will never give medical information or an answer about a particular case.